View Issue Details

IDProjectCategoryView StatusLast Update
0031621RunnerHTML5Public2020-02-26 15:37
ReporterAliceAssigned ToLuke Brown 
PriorityHighSeverityB - MajorReproducibility100%
Status ClosedResolutionFixed 
PlatformHTML5OSInternet ExplorerOS Version11 32b and 64b
Product Version2.2.5 
Target Version2.3.0Fixed in Version2.3.0 
Summary0031621: HTML5: Running projects on Internet Explorer 11 does not work when using default device target settings
DescriptionIssue:
When trying to run a project on Internet Explorer 11 (both 32bit and 64bit), when the "Web Server Address" is set to the default 127.0.0.1 on the Device target manager, the user will be asked to open the project with a different application and that the web server address cannot be found.

Please note that changing the "Web Server Address" to "http://localhost" fixes the issue.

Expected:
It is possible to run projects on Internet Explorer 11 using the default device target settings.
Steps To Reproduce1- Launch the IDE
2- Create a project
3- Set the device target to be HTLM5>Internet Explorer(either 32bit or 64bit)
4- Run the project
5- Observe the issue on the browser
Additional InformationPlease see the screenshots attached.
TagsNo tags attached.
1.4 Found In
2.x Runtime Found In2.2.5.378
2.x Runtime Verified In IDE v23.1.1.122 Runtime v23.1.1.105

Activities

Alice

2020-02-14 14:04

Adminstrator  

ieapp.jpg (90,453 bytes)
ieapp.jpg (90,453 bytes)
ieapp1.jpg (81,380 bytes)
ieapp1.jpg (81,380 bytes)

Luke Brown

2020-02-17 17:34

Developer   ~0065369

fixed in github.

Note: to test, you will need to ensure that preferences are cleared. otherwise the default webserver address will remain as "127.0.0.1" rather than "http://127.0.0.1"

Dan

2020-02-26 15:35

Adminstrator   ~0065390

^ AND you will need to fix any existing Edge/IE browser devices you have created in Device Manager (or clear your current browser list and scan again).

Dan

2020-02-26 15:37

Adminstrator   ~0065391

Works after making the above changes. Closing.